CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Guided compact cylinders 3 Pneumatic actuation 3 | 165 Series 6101 Cylinder force - Operating criteria Cylinder theoretic force (N) Working pressure 2 bar 1005 907 3 bar 1508 1361 4 bar 2011 1814 5 bar 2513 2268 6 bar 3016 2721 7 bar 3519 3175 8 bar 4021 3629 9 bar 4524 4082 10 bar 5027 4536 Effective area (mm2) Out In 5027 4536 Recommended torque moments Stroke Nm 25 49 50 41 75 51 100 45 125 41 150 38 175 35 200 32 “Stopper” device applications Load L = 50 mm Load L = 50 mm ATTENTION : max stroke 50 mm Speed (mm/s) Moving load (N)

RkJQdWJsaXNoZXIy NzYzOTY1