CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Proportional technology 2 | 177 Series 1700 - Electronic proportional regulator - Sizes 0 - 1 - 3 2 AIR TREATMENT Features * Selectable by keyboard or by RS-232 ** Valid only for devices with analog input Desired outlet pressure + 1 bar Air filtered at 5 micron and dehumidified 10 bar 0 ... 9 bar Size 0 Size 1 Size 3 7 Nl/min 1100 Nl/min 4000 Nl/min 7 Nl/min 1300 Nl/min 4500 Nl/min < 1 Nl/min < 1 Nl/min < 1 Nl/min Fluid Minimum inlet pressure Maximum inlet pressure Outlet pressure Nominal flowrate from 1 to 2 (6 bar ∆P 1 bar) Discharge flowrate (a 6 bar with 1 bar overpressure) Air consumption Supply connection Operating connection Exhaust connection Maximum fitting tightening M5 G 1/4” G 1/2” M5 G 1/4” G 1/2” Ø1,8 G 1/8” G 3/8” 3 Nm 15 Nm 15 Nm Supply voltage Standby current consumption Current consumption with solenoid valves on **Reference Signal Voltage Current **Input Impedance Voltage Current **Digital Inputs **Digital Output 24VDC ± 10% (stabilized with ripple<1%) 70mA 400mA *0 ... 10 V *0 ... 5 V *1 ... 5 V *4 ... 20 mA *0 ... 20 mA 10 kΩ 250 Ω 24VDC ± 10% 24 VDC PNP (max current 50 mA) Linearity Hysteresis Repeatability Sensitivity Assembly position Protection grade Ambient temperature ± Insensitivity ± Insensitivity ± Insensitivity 0,01 bar Indifferent IP65 (with casing fitted) -5°C ... 50°C / 23°F ... 122°F Body Shutters Diaphragm Seals Cover for electrical part Springs Weight Anodized aluminum Brass with vulcanized NBR Cloth-covered rubber NBR Technopolymer AISI 302 Size 0 Size 1 Size 3 168 g 360 g 850 g Pneumatic Electric Functional Constructional

RkJQdWJsaXNoZXIy NzYzOTY1