Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Air service units Series Airplus 2 s 2 | 37 Characteristic curves Flow rate curves Adjustment characteristic Size 4 - G1", P1=10 bar 0 2000 4000 6000 8000 10000 12000 0 1 2 3 4 5 6 7 14000 Flow Q [dm3/min] (ANR) Dowstream pressure (bar) Q=10% Qmax.= 1600 dm3/min (ANR) Q=2% Qmax.= 320 dm3/min (ANR) 1,5 2 2,5 3 0 1 2 3 4 5 6 7 8 9 10 Inlet pressure (bar) Downstream pressure (bar) Piloting curves 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 8 9 10 8 9 10 Piloting pressure (bar) Dimensions L4 D2 D1 B3 L9 L8 B1 L3 D4 D4 D3 L5 L2 B2 Model B1 B2 B3 D1 D2 D3 D4 L2 L3 L4 L5 L8 L9 #174.. 99 44 90 G1” 1 NPT G1/8” 1/8 NPT G1/4” 8.5 52.5 11 105 54.5 25 70