CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Solenoid valves manifold 1 | 430 Series 2200 "Optyma-Sc" - Configurator Module 1 ...-... Module 2 ...-... Module 3 only for 15 poles connector ...-... Right endplates P0 Endplate closed P1 Endplate with connection ports Accessory diaphragm plug (Optional) X Diaphragm plug on port 1 Y Diaphragm plug on port 3 Z Diaphragm plug on port 5 Electrical connection MP 9 Multi-pin 9 poles PNP connector 1 Multi-pin 15 poles PNP connector MN 9 Multi-pin 9 poles NPN connector 1 Multi-pin 15 poles NPN connector MA 9 Multi-pin 9 poles AC connector 1 Multi-pin 15 poles AC connector Left endplates E External feeding - - - - - - - - CONFIGURATION CODE C E Note: • 8 for multi-pin 9 poles connector (MP9) • 12 for multi-pin 15 poles connector (MP1) Consider that every base uses 4 signals and the number of avaliable signals depends on the electrical connection type, so the number of bases you can use is related to If a monostable valve is used on a bistable type base (2 electrical signals occupied), an electrical signal is lost. the electrical connection you chose. You can order a “bases only” manifold by selecting “V” option in the solenoid valves dedicated field. However, this makes it possible to replace the monostable valve with a bistable valve in the same position. Diaphragm plugs are used to interrupt ports 1, 3 and 5 of the sub-base. If it is necessary to interrupt more than one port at the same time, put the letters that identify their position in sequence (e.g.: if it is necessary to intercept the ports 3 and 5 you must put the letters YZ). Accessory diaphragm plug (Optional) only for 15 poles connector X Diaphragm plug on port 1 Y Diaphragm plug on port 3 Z Diaphragm plug on port 5 Base type 4 Bistable two-position base Ø4 6 Bistable two-position base Ø6 8 Bistable two-position base Ø8 Base version 5-1-3 free (standard sub-base) 3 Intermediate diaphragm plug on ports 1 and 5 4 Intermediate diaphragm plug on ports 1 and 3 5 Intermediate diaphragm plug on port 5 6 Intermediate diaphragm plug on ports 1, 3, 5 7 Intermediate diaphragm plug on port 1 8 Intermediate diaphragm plug on ports 3 and 5 9 Intermediate diaphragm plug on port 3 - - This selection MUST be done for every place into the manifold. It’s NOT possible to configure manifolds with positions both filled with S.V. and free. It’s possible to order an only base manifold by select the field V as described. See “single pneumatic module configurator” See “single pneumatic module configurator” See “single pneumatic module configurator” Single pneumatic module configurator Module configurator S.V. accessories (optional) 5 Separed exhaust 6 Separed air supply Solenoid valve version A S.V. 5/2 solenoid-spring B S.V. 5/2 solenoid-differential C S.V. 5/2 solenoid-solenoid E S.V. 5/3 solenoid-solenoid F S.V. 2x3/2 NC-NC G S.V. 2x3/2 NO-NO H S.V. 2x3/2 NO-NC I S.V. 2x3/2 NC-NO T Plug Only bases manifold version V No valve Accessories not available for only bases manifold Rules and configuration scheme

RkJQdWJsaXNoZXIy NzYzOTY1