CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Configurator 1 Air distribution Solenoid valves manifold ISO 15407-2 1 | 399 Series 2700 - Serial systems NOTE: While configuring the manifold always be careful that the maximum number of electrical signals available is 32. The use of monostable valve mounted on a base type 2 ( 2 electrical signals occupied ) causes the loss of one electric signal. In this case the monostable valve can be replaced by a bistable valve. The diaphragms plugs are used to intercept the conduits 1,3 & 5 of the base. If it is necessary to interrupt more than one conduit in the same time then put in line the letters which identifies the position (for exemple : regarding the 3 & 5 conduits, put the Y & Z letters). Should one or more conduits be cut more than one time it is necessary to add the relevant intermediate Supply/Exhaust module. RIGHT ENDPLATE U0 = Closed U2 = 25 Poles I/O MODULE M8 (Requires 25 poles right endplate) ACCESSORIES X = Diaphragm plug on pipe 1 Y = Diaphragm plug on pipe 3 Z = Diaphragm plug on pipe 5 XY = Diaphragm plug on pipe 1 & 3 ZX = Diaphragm plug on pipe 5 & 1 ZY = Diaphragm plug on pipe 5 & 3 ZXY = Diaphragm plug on pipe 5, 1 & 3 ACCESSORIES CONFIGURATION . . . SUB-BASE TYPE 1 = Base type 1 for Monostable (1 electrical signal occupied) 2 = Base type 2 for Bistable (2 electrical signals occupied) VALVE TYPE: A = Self-feeding E = External feeding __ __ MODUL CONFIGURATION Sub-base type Valve type __ SHORT CODE FUNCTION / CONNECTION : A= 5/2 SOLENOID - SPRING B= 5/2 SOLENOIS - DIFFERENTIAL C= 5/2 SOLENOID - SOLENOID E= 5/3 CC SOLENOID -SOLENOID F= 2x3/2 NC-NC (= 5/3 OC) SOLENOID -SOLENOID G= 2x3/2 NO-NO (= 5/3 PC) SOLENOID -SOLENOID H= 2x3/2 NC-NO SOLENOID -SOLENOID I= 2x3/2 NO-NC SOLENOID -SOLENOID T= FREE VALVE SPACE PLUG Manifold Layout configuration 32 OUT VERSION C3 D3 P3 A3 I3 N3 L3 M3 = = = = = = = = ® CANopen 32OUT DeviceNet 32OUT PROFIBUS 32OUT ® EtherCAT 32OUT (5700 Series) EtherNet / IP 32OUT PROFINET IO RT 32OUT Powerlink 32OUT Modbus/TCP 32OUT INPUT MODULES A = No module D1= 8 M8 digital inputs module D2= 8 M12 digital inputs module T1= 2 analogue inputs 0-5V module T2= 2 analogue inputs 0-10V module C1= 2 analogue inputs 0-20mA module C2= 2 analogue inputs 4-20mA module P1= 2 Pt100 inputs 2 wires module P2= 2 Pt100 inputs 3 wires module E1= 2 Pt100 inputs 2 wires module extended range E2= 2 Pt100 inputs 3 wires module extended range V27 . . __ __ __ . __ . . . . __ __ . . . . . . . __ __ __ S.V. POWER E3 = S.V. 2,3W E5 = S.V. 1W __

RkJQdWJsaXNoZXIy NzYzOTY1