CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool valves and solenoid valves 1 | 19 Series 105 - Mechanical and manual command ►Handle with valve Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +70 Flow rate at 6 bar with Δp=1 (Nl/min) 120 Orifice size (mm) 2.5 Working ports size M5 - Quick Fitting for Ø4 tube Coding: 105.T.6.A.F T TYPE 32 = 3 ways 52 = 5 ways A FEEDING 40 = Left feeding 40D = Right feeding F FUNCTION (only for 3 ways) A = Normally Open C = Normally Closed Weight 165 g Operating force 14 N 105.32.6.40.F Left feeding Weight 190 g Operating force 14 N 105.52.6.40 Right feeding Weight 190 g Operating force 14 N 105.52.6.40.D

RkJQdWJsaXNoZXIy NzYzOTY1