Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution ISO 5599-1 Valves and solenoid valves 1 | 286 Series 1000 M12 - Size 3 ►Solenoid-Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Minimum pilot pressure (bar) 2.5 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 3600 Response time according to ISO 12238, activation time (ms) 46 Response time according to ISO 12238, deactivation time (ms) 254 Weight 1360 g 66 195,5 32 64 48 87,5 M12x1 Ø8,5 Coding: 1113.52.3.9.T T VOLTAGE 12P = 24VDC 2 1 3 4 5 ►Solenoid-Differential Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Minimum pilot pressure (bar) 2 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 3600 Response time according to ISO 12238, activation time (ms) 78 Response time according to ISO 12238, deactivation time (ms) 180 Weight 1360 g 66 195,5 32 64 48 87,5 M12x1 Ø8,5 Coding: 1113.52.3.6.T T VOLTAGE 12P = 24VDC 2 1 3 4 5