CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution ISO 5599-1 Valves and solenoid valves 1 | 283 Series 1000 M12 - Size 1 ►Solenoid-Solenoid 5/2 Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Minimum pilot pressure (bar) 1.5 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 900 Response time according to ISO 12238, activation time (ms) 13 Response time according to ISO 12238, deactivation time (ms) 14 Weight 390 g M12x1 68 36 Ø5.5 42 18 28 125 Coding: 1111.52.3.5.T T VOLTAGE 12P = 24VDC 2 1 3 4 5 ►Solenoid-Solenoid 5/3 Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Minimum pilot pressure (bar) 3 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 900 Response time according to ISO 12238, activation time (ms) 18 (Closed centres) 18 (Open centres) 19 (Pressured centres) Response time according to ISO 12238, deactivation time (ms) 19 (Closed centres) 20 (Open centres) 18 (Pressured centres) Weight 392 g M12x1 68 36 Ø5.5 42 18 28 125 Coding: 1111.53.F.3.5.T F FUNCTION 31 = Closed centres 32 = Open centres 33 = Pressured centres T VOLTAGE 12P = 24VDC 2 1 3 4 5 2 1 3 4 5 2 1 3 4 5

RkJQdWJsaXNoZXIy NzYzOTY1