CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution ISO 5599-1 Valves and solenoid valves 1 | 282 Series 1000 M12 - Size 1 ►Solenoid-Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Minimum pilot pressure (bar) 2.5 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 900 Response time according to ISO 12238, activation time (ms) 16 Response time according to ISO 12238, deactivation time (ms) 122 Weight 350 g M12x1 68 36 Ø5.5 42 18 125 28 Coding: 1111.52.3.9.T T VOLTAGE 12P = 24VDC 2 1 3 4 5 ►Solenoid-Differential Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Minimum pilot pressure (bar) 2 Temperature °C -5 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 900 Response time according to ISO 12238, activation time (ms) 32 Response time according to ISO 12238, deactivation time (ms) 51 Weight 356 g M12x1 68 36 Ø5.5 42 18 125 28 Coding: 1111.52.3.6.T T VOLTAGE 12P = 24VDC 2 1 3 4 5