CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice “NAMUR” valves and solenoid valves Series 515 High Performance 1 Air distribution 1 | 261 Order codes Connections 5 : G1/4” - supplied without plate 7 : 1/4” NPT - supplied without plate 5 . . B04 Model : Standard valve X : ATEX valve (-20°C ... +40°C) - only with solenoid coils “B##”,“C##” e “X##” (-30°C ... +50°C) - only with solenoid coils “MHC”,“MH#” . . 39 51 00 Version 16: Pneumatic-Differential 18: Pneumatic-Pneumatic 19: Pneumatic-Spring 35: Solenoid-Solenoid 36: Solenoid-Differential 39: Solenoid-Spring 52 Temperature options : Standard valve (-10°C ... +50°C) LT : Low temperature (-30°C ... +50°C) Example: 515.52.00.39.B04: Standard valve, G1/4” connections supplied without plate, solenoid-spring 5 ways, 12 VDC solenoid coil Voltages Valve marking with ATEX solenoid coil Protection method of the ATEX solenoid coil B00: Ø10 stem without solenoid coil to be used with the following solenoid coils / B04: 12 V DC - for all models Ex ec Ex tc B05: 24 V DC - for all models B09: 24 V DC (2W) - only for standard model B56: 24 V AC (50-60 Hz) - for all models B57: 110 V AC (50-60 Hz) - for all models B58: 230 V AC (50-60 Hz) - for all models C04: 12 V DC - for all models C05: 24 V DC - for all models C09: 24 V DC (2W) - only for standard model C56: 24 V AC (50-60 Hz) - for all models C57: 110 V AC (50-60 Hz) - for all models C58: 230 V AC (50-60 Hz) - for all models F00: Ø9 stem without solenoid coil to be used with the following solenoid coils / X05: 24 V DC - only for ATEX model Ex mb X56: 24 V AC (50-60 Hz) - only for ATEX model X57: 110 V AC (50-60 Hz) - only for ATEX model X58: 230 V AC (50-60 Hz) - only for ATEX model MHC: 24 V DC T6 - only for ATEX model complete with connector Ex ia MH4: 24 V DC T4 - only for ATEX model Ex ia MH6: 24 V DC T6 - only for ATEX model Electrical specifications for intrinsically safety Group IIC Ui max= 28 V, li max= 115 mA, Pi max= 1,6 W Group IIB Ui max= 32 V, li max= 195 mA, Pi max= 1,6 W Voltages Solenoid coil marking L04: 12 V DC - only for FM APPROVED model L05: 24 V DC - only for FM APPROVED model L39: 120 V AC - only for FM APPROVED model L41: 240 V AC - only for FM APPROVED model FM APPROVED valve (-20°C ... +50°C) - only with solenoid coils “L##” II 2G Ex h IIC T5 Gb X II 2D Ex h IIIC T96°C Db X : II 3G Ex h IIC T4 Gc X II 3D Ex h IIIC T120°C Dc X IP65 : II 2G Ex h IIC T5 Gb X II 2D Ex h IIIC T96°C Db X : II 2G Ex h IIC T4 Gb X II 2D Ex h IIIC T135°C Db X IP65 : II 2G Ex h IIB/IIC T4 Gb X II 2D Ex h IIIC T130°C Db X IP65 : II 2G Ex h IIB/IIC T4 Gb X :

RkJQdWJsaXNoZXIy NzYzOTY1