CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice “NAMUR” valves and solenoid valves Series 515 High Performance 1 Air distribution 1 | 261 Order codes Connections 5 : G1/4” - supplied without plate 7 : 1/4” NPT - supplied without plate Function and version 52.00.16: 5 ways - Pneumatic-Differential 52.00.18: 5 ways - Pneumatic-Pneumatic 52.00.19: 5 ways - Pneumatic-Spring 52.00.35: 5 ways - Solenoid-Solenoid 52.00.36: 5 ways - Solenoid-Differential 52.00.39: 5 ways - Solenoid-Spring 51 5 . B04 52.00.39 Model : Standard valve X : ATEX valve (-20°C ... +40°C) - only with solenoid coils “B##”,“C##” e “X##” (-30°C ... +50°C) - only with solenoid coils “MHC”,“MH#” . Temperature options : Standard valve (-10°C ... +50°C) LT : Low temperature (-30°C ... +50°C) Voltages Valve marking with ATEX solenoid coil Protection method of the ATEX solenoid coil B00: Ø10 stem without solenoid coil to be used with the following solenoid coils / B04: 12 VDC - for all models Ex ec Ex tc B05: 24 VDC - for all models B09: 24 VDC (2W) - only for standard model B56: 24 VAC (50-60 Hz) - for all models B57: 110 VAC (50-60 Hz) - for all models B58: 230 VAC (50-60 Hz) - for all models C04: 12 VDC - for all models C05: 24 VDC - for all models C09: 24 VDC (2W) - only for standard model C56: 24 VAC (50-60 Hz) - for all models C57: 110 VAC (50-60 Hz) - for all models C58: 230 VAC (50-60 Hz) - for all models F00: Ø9 stem without solenoid coil to be used with the following solenoid coils / X05: 24 VDC - only for ATEX model Ex mb X56: 24 VAC (50-60 Hz) - only for ATEX model X57: 110 VAC (50-60 Hz) - only for ATEX model X58: 230 VAC (50-60 Hz) - only for ATEX model MHC: 32 VDC T6 - only for ATEX model complete with connector Ex ia MH4: 32 VDC T4 - only for ATEX model Ex ia MH6: 32 VDC T6 - only for ATEX model Voltages Valve marking with FM solenoid coil L04: 12 VDC - only for FM APPROVED model L05: 24 VDC - only for FM APPROVED model L39: 120 VAC - only for FM APPROVED model L41: 240 VAC - only for FM APPROVED model FM APPROVED valve (-20°C ... +50°C) - only with solenoid coils “L##” II 2G Ex h IIC T5 Gb X II 2D Ex h IIIC T96°C Db X : II 3G Ex h IIC T4 Gc X II 3D Ex h IIIC T120°C Dc X IP65 : II 2G Ex h IIC T5 Gb X II 2D Ex h IIIC T96°C Db X : II 2G Ex h IIC T4 Gb X II 2D Ex h IIIC T135°C Db X IP65 : II 2G Ex h IIB/IIC T4 Gb X II 2D Ex h IIIC T130°C Db X IP65 : II 2G Ex h IIB/IIC T4 Gb X : Example : 515.52.00.39.B04 : Standard valve, G1/4” connections supplied without plate, solenoid-spring 5 ways, 12 VDC solenoid coil

RkJQdWJsaXNoZXIy NzYzOTY1