CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice “NAMUR” valves and solenoid valves Series T514 1 Air distribution 1 | 250 ►Pneumatic - Differential Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Temperature °C -10 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1100 Orifice size (mm) 8 Working ports size G 1/4" Coding: T514.T.00.16 T TYPE 42 = 4 ways, 2 positions 52 = 5 ways, 2 positions 4/2 ways Weight 140 g Minimum working pressure 2,5 bar Maximum fitting torque 9 N/m T514.42.00.16 2 1 3 4 12 5/2 ways Weight 140 g Minimum working pressure 2,5 bar Maximum fitting torque 9 N/m T514.52.00.16 2 1 3 4 5 14 ►Pneumatic-Pneumatic Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max. working pressure (bar) 10 Temperature °C -10 ... +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1100 Orifice size (mm) 8 Working ports size G 1/4" Coding: T514.T.00.18 T TYPE 42 = 4 ways, 2 positions 52 = 5 ways, 2 positions 4/2 ways Weight 140 g Minimum working pressure 2,5 bar Maximum fitting torque 9 N/m T514.42.00.18 2 1 3 4 12 10 5/2 ways Weight 140 g Minimum working pressure 2,5 bar Maximum fitting torque 9 N/m T514.52.00.18 2 1 3 4 5 14 12