Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool valves and solenoid valves 1 | 5 Series 104 - Mechanical and manual command ►Palm button 2 position Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +70 Flow rate at 6 bar with Δp=1 (Nl/min) 90 Orifice size (mm) 2.5 Working ports size ø4 tube Coding: 104.T.6.25.W.F T TYPE 22 = 2 ways 32 = 3 ways 52 = 5 ways W CONNECTION TYPE L = Lateral P = Rear F FUNCTION (only for 2/2 and 3/2 ways) A = Normally Open C = Normally Closed 2/2 - 3/2 - Lateral connections Weight 65 g Operating force 19 N Emergency - Rotate to unlock 104.T.6.25.L.F 2/2 - 3/2 - Rear connections Weight 65 g Operating force 19 N Emergency - Rotate to unlock 104.T.6.25.P.F 5/2 - Lateral connections Weight 120 g Operating force 32 N Emergency - Rotate to unlock 104.52.6.25.L 5/2 - Rear connections Weight 120 g Operating force 32 N Emergency - Rotate to unlock 104.52.6.25.P