CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 Air distribution Spool valves and solenoid valves 1 | 172 Series 2600 - Size 26mm VDMA ►Pneumatic - Spring Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1100 Orifice size (mm) 7.5 Weight 235 g Minimum piloting pressure 2 bar Coding: 2645.52.00.19 ►Pneumatic - Differential Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1100 Orifice size (mm) 7.5 Weight 235 g Minimum piloting pressure 2 bar Coding: 2645.52.00.16 ►Pneumatic - Differential (External) Operational characteristics Fluid Filtered air. No lubrication needed, if applied it shall be continuous Max working pressure (bar) 10 Temperature °C -5 ÷ +50 Flow rate at 6 bar with Δp=1 (Nl/min) 1100 Orifice size (mm) 7.5 Weight 235 g Minimum piloting pressure 2 bar Coding: 2645.52.00.17