CATGEN-EN

Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Magnetic sensors 3 | 251 Series SA - REED style versions 3 Pneumatic actuation ►Cable sensor Technical characteristics A.C. D.C. U U/1 A.C. D.C. A.C. D.C. Permanent maximum current 1,5A 1,2A 0,5A 0,3A Maximum current (0.5 sec. pulses) 6A 1,5A 1A 0,8A Voltage field 12 ... 230V 12 ... 30V 3 ... 230V 12 ... 48V 0 ... 230V 0 ... 48V Permanent maximum power 375VA 32W 20VA 15W 10VA 8W Working temperature -20°C ... 70°C Maximum voltage drop 3V max 2V max 3V max 0V Cable length 2m Cable colour Black External cable section Ø4,2mm Cover material PUR Number of wires in the cable 2 Wires section 0,34 mm² Connection type With cable without connector Protection degree IP65 Switch-on time 2 ms Switch-off time 1 ms Average working time 107cycles Repetition of intervention point ± 0,1 mm Contact type N.O. Directive CE as set out in Directive 2014/30/EU UKCA pursuant to U.K. S.I. Regulation 2016 No. 1091 Fixing With screw Weight 50g With LED indication With LED Without LED LED color Red / Cylinders and microcylinders 12 16.2 5.5 2.5 27 15,5 14,5 Slot detail type “A” Coding: 1T00.V T TYPE 5 = Cylinders and microcylinders. Slot detail type “A”. 6 = Rodless cylinders V VERSION AC = For alternating current DC = For continuous current U = Universal U/1 = Universal sensor (REED ampulla only) Rodless cylinders 27 12 14,5 Diagrams and connections AC DC U U/1 brown blue LOAD ~ ~ LOAD brown blue LOAD ~ ~ brown blue LOAD ~ ~ brown blue *The load (LOAD) can be connected either to negative or positive pole.

RkJQdWJsaXNoZXIy NzYzOTY1