Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice Vane type rotary actuators Series 6420 Pneumatic actuation 3 3 | 228 Switch positioning instructions Ø50 ... Ø100 Phase 1: unfasten screw A Phase 2: assemble the switch C into the dedicated housing B and lock with screw D Phase 3: rotate block B in the desired position (see following image) A B C D Locking screw block Block Sensor Switch fixing screw 270° 180° 90° ˜ ˜ ˜ Connection 2 Connection 1 Connection 2 Connection 1 Connection 2 Connection 1 α: magnet rotating angle (that corresponds to the shaft key flat rotating angle) For correct functionality position the switch within angle α Phase 4: tighten screw A Phase 5: repeat the following phases for the second switch AVAILABLE SENSORS Code 1583.DC 1583.HAP THR.P